Nuclear Engineering and Technology (Mar 2020)

Development of Parallel Plate Avalanche Counter for heavy ion collision in radioactive ion beam

  • Xianglun Wei,
  • Fenhai Guan,
  • Herun Yang,
  • Yijie Wang,
  • Junwei Zhang,
  • Peng Ma,
  • Xinyue Diao,
  • Chengui Lu,
  • Meng Li,
  • Yuanfan Guan,
  • Limin Duan,
  • Rongjiang Hu,
  • Xiuling Zhang,
  • Zhigang Xiao

Journal volume & issue
Vol. 52, no. 3
pp. 575 – 580

Abstract

Read online

We have developed a position-sensitive Parallel Plate Avalanche Counter (PPAC) to detect the fission fragments and reconstruct the fission reaction plane in the experiment of studying nuclear equation of state (nEOS) by means of heavy ion collision (HIC). This experiment put forward high requirements for the performances of PPAC, such as the time resolution, efficiency and position resolution. According to these requirements we designed the PPAC with an active area of 240 mm × 280 mm working at low gas pressure. The results show that time resolution could be less than 300 ps. Position resolution is consistent with the theoretical calculation about 1.35 mm. Detection efficiency could be approaching 100% gradually with the voltage increasing in different gas pressures. The performances of PPAC have also been verified in beam experiment. Each set of anode wires can be accurately separated in the position spectrum. In the beam experiment, we also got the back-to-back correlation of fission fragments which is one of the direct signals characterizing binary decay. Keywords: PPAC, nEOS, Time resolution, Position resolution, Efficiency