Tzu-Chi Medical Journal (Jan 2019)

In vivo assessment of endothelial function in small animals using an infrared pulse detector

  • Cyuan-Cin Liu,
  • Wei-Min Liu,
  • Hsien-Tsai Wu,
  • Chien-Hsing Wang,
  • An-Bang Liu

DOI
https://doi.org/10.4103/tcmj.tcmj_94_18
Journal volume & issue
Vol. 31, no. 4
pp. 217 – 221

Abstract

Read online

Objective: Endothelial dysfunction is the earliest change in atherosclerosis. Flow-mediated dilatation (FMD) is used to assess endothelial function in humans. However, this assessment is not easy in small animals. This study demonstrated the reliability and reproducibility of a proposed instrument for in vivo assessment of FMD in a rodent model using infrared pulse sensors. Materials and Methods: We used 24 adult male Wistar Kyoto rats randomly divided into three groups. FMD was measured under continuous infusion of normal saline followed by intra-arterial infusion of acetylcholine (Ach; n = 8), sodium nitroprusside (SNP; n = 8), or N∞-nitro-L-arginine methyl ester (L-NAME; n = 8). Results: The dilatation indices (DIs) of all three groups were similar before application of the vasoactive agents (1.82 ± 0.46, 1.81 ± 0.44, and 1.93 ± 0.40, P = 0.877, by one-way analysis of variance). The DI was significantly increased during infusion of Ach (2.97 ± 1.03 vs. 1.82 ± 0.46, P = 0.015), unchanged during infusion of SNP (1.81 ± 0.44 vs. 1.98 ± 0.40, P = 0.574), and attenuated during infusion of L-NAME (1.91 ± 0.40 vs. 1.42 ± 0.35; P = 0.028). Conclusion: The results of this study correlated well with those of human studies, suggesting that this method can be used for in vivo evaluation of endothelial function in small animals.

Keywords