Arthroscopy Techniques (Dec 2015)

Perineal Post Padding Technique to Improve Hip Distraction in Tall Patients

  • Benjamin D. Kuhns, M.S.,
  • Brandon J. Erickson, M.D.,
  • Leah R. Bressler, M.S., P.A-C.,
  • Sara M. Sarmast, M.M.S., P.A-C.,
  • Shane J. Nho, M.D., M.S.

Journal volume & issue
Vol. 4, no. 6
pp. e747 – e750

Abstract

Read online

Hip distraction is necessary for safe arthroscopic entry into the hip joint. Achieving sufficient distraction is difficult in exceedingly tall patients (>190.5 cm) because of size limitations of currently available hip distraction systems. Inadequate distraction can delay the surgical procedure and potentially lead to complications. By repurposing a foam head-positioning block, we report a safe and inexpensive positioning technique for extending the traction distance for tall patients by 2 inches.