Physics Open (Feb 2024)

Measurement of leakage neutron flux from reactor tank surface of AHWR-critical facility

  • Kapil Deo,
  • A.K. Mallick,
  • Deep Bhandari,
  • Rajeev Kumar,
  • Umasankari Kannan

Journal volume & issue
Vol. 18
p. 100193

Abstract

Read online

AHWR - Critical Facility (AHWR - CF) is a “zero power” reactor designed to carry out various reactor physics experiments for validation of AHWR physics design. AHWR-CF is a vertical tank type reactor. This paper describes the experiments carried out for neutron flux measurements on the reactor tank surface of AHWR-CF. A number of bare Au and cadmium covered Ni foils were used to measure thermal and fast neutron flux at the outer surface of the reactor tank. One cadmium covered Au foil was also irradiated at one of the locations on the tank surface, to estimate the epithermal component of neutron flux. Westcott thermal flux on the tank surface (at an elevation of 120 cm from tank bottom) was found to be (5.48 ± 0.57)E+6 n cm−2 s−1 on one of the sides of the reactor tank. Cadmium ratio for Au for this location was 40.28, indicating a highly thermalized neutron spectrum. No statistically significant activity was found in the irradiated Ni foils, indicating the absence of fast neutron flux above the measurable threshold. Low value of flux on the reactor tank surface implies that any irradiation damage in the AHWR-CF reactor tank material will be insignificant over its period of operation.

Keywords