PLoS ONE (Jan 2020)
Prediction and discrimination of skeletal muscle function by bioelectrical impedance vector analysis using a standing impedance analyzer in healthy Taiwanese adults.
Abstract
BackgroundBioelectrical impedance vector analysis (BIVA) has been used for prediction of muscle performance. However, little is known about BIVA in Asian adults, and even less is known about using standing BIVA devices. Standing impedance analyzer allows quicker and more convenient way to gather data than conventional supine analyzer and is more suitable for clinical practice. This study aimed to investigate the relations between muscle function and BIVA parameters measured with a standing impedance analyzer in healthy Taiwanese adults.MethodsA total of 406 healthy subjects (age 34.5 ± 17.3 years, body mass index 24.1 ± 4.1 kg/m2) were recruited for BIVA and handgrip strength (HGS) measurements. Impedance parameters, including resistance (R) and reactance (Xc), were measured and normalized to body size by dividing by height (H). The resulting phase angle (PhA) was calculated. HGS in the dominant, left, and right hands were referred to as HGSDH, HGSLH, and HGSRH, respectively. All subjects were divided into 5 grades according to HGS.ResultsMuscle strength in the dominant, right, and left arms was correlated with variables in the order of sex, weight, age, height, Xc/H, and R/H (all, p ConclusionsBIVA parameters measured with a standing impedance analyzer and anthropometric variables can predict and discriminate muscle function with good performance in healthy Asian adults.