Real-Time Tracheal Ultrasound vs. Capnography for Intubation Confirmation during CPR Wearing a Powered Air-Purifying Respirator in COVID-19 Era
Seungwan Eun,
Hee Yoon,
Soo Yeon Kang,
Ik Joon Jo,
Sejin Heo,
Hansol Chang,
Guntak Lee,
Jong Eun Park,
Taerim Kim,
Se Uk Lee,
Sung Yeon Hwang,
Sun-Young Baek
Affiliations
Seungwan Eun
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Hee Yoon
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Soo Yeon Kang
Department of Emergency Medicine, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong-si 14353, Republic of Korea
Ik Joon Jo
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Sejin Heo
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Hansol Chang
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Guntak Lee
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Jong Eun Park
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Taerim Kim
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Se Uk Lee
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Sung Yeon Hwang
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06355, Republic of Korea
Sun-Young Baek
Biomedical Statistics Center, Data Science Research Institute, Research Institute for Future Medicine, Samsung Medical Center, Seoul 06351, Republic of Korea
This study aimed to compare the accuracy of real-time trans-tracheal ultrasound (TTUS) with capnography to confirm intubation in cardiopulmonary resuscitation (CPR) while wearing a powered air-purifying respirator (PAPR). This setting reflects increased caution due to contagious diseases. This single-center, prospective, comparative study enrolled patients requiring CPR while wearing a PAPR who visited the emergency department of a tertiary medical center from December 2020 to August 2022. A physician performed the TTUS in real time and recorded the tube placement assessment. Another healthcare provider attached waveform capnography to the tube and recorded end-tidal carbon dioxide (EtCO2) after five ventilations. The accuracy and agreement of both methods compared with direct laryngoscopic visualization of tube placement, and the time taken by both methods was evaluated. Thirty-three patients with cardiac arrest were analyzed. TTUS confirmed tube placement with 100% accuracy, sensitivity, and specificity, whereas capnography demonstrated 97% accuracy, 96.8% sensitivity, and 100% specificity. The Kappa values for TTUS and capnography compared to direct visualization were 1.0 and 0.7843, respectively. EtCO2 was measured in 45 (37–59) seconds (median (interquartile range)), whereas TTUS required only 12 (8–23) seconds, indicating that TTUS was significantly faster (p 2 measurement for confirming endotracheal tube placement during CPR, particularly in the context of PAPR usage in pandemic conditions.