High Voltage (Aug 2024)

Degradation of superhydrophobic aluminium overhead line conductor surfaces

  • Xu Zhang,
  • Chorphaka Plaengpraphan,
  • Chengxing Lian,
  • Wenyuan Li,
  • Qinghua Han,
  • Simon M. Rowland,
  • Ian Cotton,
  • Qi Li

DOI
https://doi.org/10.1049/hve2.12455
Journal volume & issue
Vol. 9, no. 4
pp. 763 – 772

Abstract

Read online

Abstract It has been shown that noise emissions from HV overhead line conductors can be reduced under rain conditions by making their surfaces superhydrophobic. The working environment makes ensuring the longevity of any treatment a major challenge. The degradation of various superhydrophobic surfaces generated by applying a superhydrophobic coating and patterning microscale channels is assessed under an AC electric field (18 kV/cm) with continuous water spray. By examining the droplet distribution on the surfaces during the degradation and the surface roughness before and after degradation, the authors demonstrate that no water droplets were found on the microscale patterned surface, but droplets were formed on the coated surface after degradation. The surface roughness reduction of the coated surface and microscale patterned surface was 29.8% and 11.3%, respectively, indicating that the microscale patterned surface has better durability than the superhydrophobic coating under the AC electric stress.