Journal of Laboratory Physicians (Jul 2014)

The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users

  • Rahul Bhargava,
  • Prachi Kumar,
  • Avinash Kaur,
  • Manjushri Kumar,
  • Anurag Mishra

DOI
https://doi.org/10.4103/0974-2727.141507
Journal volume & issue
Vol. 6, no. 02
pp. 102 – 108

Abstract

Read online

Aims and Objectives: To compare the diagnostic value and accuracy of dry eye scoring system (DESS), conjunctival impression cytology (CIC), tear film breakup time (TBUT), and Schirmer's test in computer users. Methods: A case-control study was done at two referral eye centers. Eyes of 344 computer users were compared to 371 eyes of age and sex matched controls. Dry eye questionnaire (DESS) was administered to both groups and they further underwent measurement of TBUT, Schirmer's, and CIC. Correlation analysis was performed between DESS, CIC, TBUT, and Schirmer's test scores. A Pearson's coefficient of the linear expression (R 2) of 0.5 or more was statistically significant. Results: The mean age in cases (26.05 ± 4.06 years) was comparable to controls (25.67 ± 3.65 years) (P = 0.465). The mean symptom score in computer users was significantly higher as compared to controls ( P 0.5), in contrast to Schirmer's scores (R 2 < 0.5). Duration of computer usage had a significant effect on dry eye symptoms severity, TBUT, and CIC scores as compared to Schirmer's test. Conclusion: DESS should be used in combination with TBUT and CIC for dry eye evaluation in computer users.