Annals of Pediatric Cardiology (Jan 2017)

Removal of a retained intracardiac radiolucent guidewire fragment using an Atrieve™ vascular snare using combined fluoroscopy and transesophageal echocardiography guidance in an infant

  • Asif Padiyath,
  • Eudice E Fontenot,
  • Boban P Abraham

DOI
https://doi.org/10.4103/0974-2069.197068
Journal volume & issue
Vol. 10, no. 1
pp. 65 – 68

Abstract

Read online

Retained intravascular foreign body is a well-known complication of central venous access placement in children as well as adults. Most of these foreign bodies are radio-opaque and hence are removed under fluoroscopy guidance. In our case, we describe the removal of an intracardiac radiolucent foreign body in an infant utilizing a combination technique - transesophageal echocardiogram and fluoroscopy.