Advances in Meteorology (Jan 2019)

Comparison of Simulations of Updraft Mass Fluxes and Their Response to Increasing Aerosol Concentration between a Bin Scheme and a Bulk Scheme in a Deep-Convective Cloud System

  • Seoung Soo Lee,
  • Chang-Hoon Jung,
  • Sen Chiao,
  • Junshik Um,
  • Yong-Sang Choi,
  • Won Jun Choi

DOI
https://doi.org/10.1155/2019/9292535
Journal volume & issue
Vol. 2019

Abstract

Read online

Key microphysical processes whose parameterizations have substantial impacts on the simulation of updraft mass fluxes and their response to aerosol are investigated in this study. For this investigation, comparisons of these parameterizations are made between a bin scheme and a bulk scheme. These comparisons show that the differences in the prediction of cloud droplet number concentration (CDNC) between the two schemes determine whether aerosol-induced invigoration of updrafts or convection occurs. While the CDNC prediction leads to aerosol-induced invigoration of updrafts and an associated 20% increase in the peak value of the updraft-mass-flux vertical profile in the bin scheme, it leads to aerosol-induced suppression of updrafts and an associated 7% decrease in the peak value in the bulk scheme. The comparison also shows that the differences in ice processes, in particular, in the snow loading lead to the different vertical patterns of the updraft-mass-flux profile, which is represented by the peak value and its altitude, between the schemes. Higher loading of snow leads to around 20–30% higher mean peak value and its around 40% higher altitude in the bin scheme than in the bulk scheme. When differences in the CDNC prediction and ice processes are removed, differences in the invigoration and the vertical pattern disappear between the schemes. However, despite this removal, differences in the magnitude of updraft mass fluxes still remain between the schemes. Associated with this, the peak value is around 10% different between the schemes. Also, after the removal, there are differences in the magnitude between cases with different aerosol concentrations for each scheme. Associated with this, the peak value is also around 10% different between those cases for each scheme. The differences between the cases with different aerosol concentrations for each scheme are generated by different evaporative cooling and different intensity of gust fronts between those cases. The remaining differences between the schemes are generated by different treatments of collection and sedimentation processes.