Arquivos Brasileiros de Cardiologia (May 2012)

Valor prognóstico da troponina I de alta sensibilidade versus troponina T nas síndromes coronarianas agudas Prognostic value of high-sensitivity troponin I versus troponin T in acute coronary syndromes

  • Luis Cláudio Lemos Correia,
  • Fábio L. Sodré,
  • José C.C. Lima,
  • Michael Sabino,
  • Mariana Brito,
  • Guilherme Garcia,
  • Mayara Maraux,
  • Alexandre C. Sousa,
  • Márcia Noya Rabelo,
  • J. Péricles Esteves

Journal volume & issue
Vol. 98, no. 5
pp. 406 – 412

Abstract

Read online

FUNDAMENTO: Apesar da superior precisão diagnóstica das troponinas cardíacas de alta sensibilidade, seu valor prognóstico ainda não foi validado contra troponinas cardíacas convencionais. OBJETIVO: Testar o valor prognóstico da troponina I de alta sensibilidade (TnI-as) em comparação com a troponina T convencional (TnT-c) no cenário de síndromes coronarianas agudas sem supradesnivelamento do segmento ST (SCA). MÉTODOS: No momento da admissão, uma amostra de plasma foi coletada de 103 pacientes consecutivos com angina instável ou infarto agudo do miocárdio sem supradesnivelamento do segmento ST. Nessa amostra, a troponina foi medida tanto pelo método TnI-as quanto pelo método TnT-c. O valor prognóstico das duas troponinas foi comparado em relação à ocorrência de evento cardiovascular maior, definido como o composto de morte, infarto agudo do miocárdio não fatal ou angina instável refratária durante a internação. RESULTADOS: Durante uma hospitalização mediana de 8 dias (intervalo interquartil = 5-11), a incidência de eventos cardiovasculares foi 10% (5 mortes, 3 infartos não fatais e 2 anginas refratárias não fatais). Troponina I de alta sensibilidade predisse significativamente eventos cardiovasculares, com C-estatísticas de 0,73 (95% CI = 0,59-0,87), à semelhança da TnT-c (0,70; 95% CI = 0,55-0,84) - P = 0,75. A definição de troponina positiva que proporcionou melhor acurácia prognóstica foi TnI-as > 0,055 mg / L e TnT-c > 0,010 mg / L, com sensibilidade de 90% e especificidade de 52% para ambos os ensaios. CONCLUSÃO: Troponina I de alta sensibilidade prediz eventos cardiovasculares de forma semelhante à troponina T convencional no cenário de SCA. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0)BACKGROUND: Despite superior diagnostic accuracy of high-sensitivity cardiac troponins, their prognostic value has not been validated against conventional cardiac troponins. OBJECTIVE: To test the prognostic value of high-sensitivity cardiac troponin I (hs-cTnI), compared with conventional cardiac troponin T (cTnT) in the setting of non-ST elevation acute coronary syndromes. METHODS: At hospital admission, a plasma sample was collected from 103 consecutive patients with unstable angina or non-ST elevation acute myocardial infarction. In this sample, troponin was measured both by hs-cTnI and cTnT methods. Their prognostic value was compared as to the occurrence of major cardiovascular events, defined as a combination of death, nonfatal acute myocardial infarction or refractory unstable angina during hospitalization. RESULTS: During median hospitalization of 8 days (interquartile range = 5 - 11), the incidence of cardiovascular events was 10% (5 deaths, 3 non-fatal myocardial infarctions and 2 non-fatal refractory anginas). High-sensitivity troponin I significantly predicted cardiovascular events, with a C-statistics of 0.73 (95% CI = 0.59 - 0.87), similarly to cTnT (0.70; 95% CI = 0.55 - 0.84) - P = 0.75. The definition of positive cardiac marker that provided the best prognostic accuracy was hs-cTnI > 0.055 µg/L and cTnT > 0.010 µg/L, with equal sensitivity of 90% and specificity of 52% for both assays. Positive hs-cTnI was associated with 17% incidence of events, compared with 2% in patients with negative hs-cTnI (P = 0.02). CONCLUSION: High-sensitivity troponin I predicts cardiovascular events similarly to conventional troponin T in the setting of non-ST-elevation ACS. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0)

Keywords