Meikuang Anquan (Aug 2023)

Advance detection technology of three-point source DC method based on COMSOL

  • GAO Weifu, WANG Kewei, HU Anshun, WANG Naijun

DOI
https://doi.org/10.13347/j.cnki.mkaq.2023.08.023
Journal volume & issue
Vol. 54, no. 8
pp. 168 – 172

Abstract

Read online

When the traditional single point power supply electrode DC advance detection technology is used to detect the long-distance anomaly, the signal gradually weakens and the accuracy greatly decreases with the increase of detection distance. In order to solve the problem of large error in long distance advance detection, we combine the existing DC method advance detection technology to change the power supply from single point source to three-point source, use COMSOL software to simulate, draw the apparent resistivity curve of the survey line, and draw the apparent resistivity profile through SURFER. The results show that the three-point source power supply can better reflect the location of the remote abnormal body, increase the effective distance of advance detection, and improve the accuracy of advance detection.

Keywords