Scientific Reports (Jan 2023)

Three-dimensional soft tissue landmark detection with marching cube algorithm

  • Yoonjung Lee,
  • Ji-Min Lee,
  • Sun-Hyung Park,
  • Yoon Jeong Choi,
  • Sung-Hwan Choi,
  • Jae Joon Hwang,
  • Hyung-Seog Yu

DOI
https://doi.org/10.1038/s41598-023-28792-w
Journal volume & issue
Vol. 13, no. 1
pp. 1 – 12

Abstract

Read online

Abstract Current method of analyzing three-dimensional soft tissue data, especially in the frontal view, is subjective and has poor reliability. To overcome this limitation, the present study aimed to introduce a new method of analyzing soft tissue data reconstructed by marching cube algorithm (Program S) and compare it with a commercially available program (Program A). Cone-beam computed tomography images of 42 patients were included. Two orthodontists digitized six landmarks (pronasale, columella, upper and lower lip, right and left cheek) twice using both programs in two-week intervals, and the reliability was compared. Furthermore, computer-calculated point (CC point) was developed to evaluate whether human error could be reduced. The results showed that the intra- and inter-examiner reliability of Program S (99.7–100% and 99.9–100%, respectively) were higher than that of Program A (64.0–99.9% and 76.1–99.9%, respectively). Moreover, the inter-examiner difference of coordinate values and distances for all six landmarks in Program S was lower than Program A. Lastly, CC point was provided as a consistent single point. Therefore, it was validated that this new methodology can increase the intra- and inter-examiner reliability of soft tissue landmark digitation and CC point can be used as a landmark to reduce human error.