Tikrit Journal of Engineering Sciences (May 2013)

Statistical Study for Some Variables in Biological Treatment for Different Type of Wastes

  • Lilyan Yaqob Mati,
  • Zena F. Al Hashemi

Journal volume & issue
Vol. 16, no. 3
pp. 18 – 25

Abstract

Read online

In this work four types of wastewater namely domestic, dairy, sugar and textile are used to perform statistical analysis. These wastes are treated by extended aeration system. Inlet and outlet COD and S.S are used to make the statistical correlation for F/M range of 0.1-1. The results showed that the relation between COD and SS is linear for domestic, dairy and sugar waste having a correlation coefficient 0.9323, 0.8774 and 0.8698 respectively. The relation is of third degree for textile waste with correlation coefficient of 0.557 due to chemicals and heavy metals. The relation between F/M and COD for all wastes is linear. To predict COD value leaving treatment plant using F/M and SS values which are allowed to be thrown to the water body, Duncan test was made depending on outlet COD and SS which show that extended aeration is not suitable for textile waste.

Keywords