Chemistry (Apr 2022)

In Situ FBG Monitoring of a Henequen-Epoxy Biocomposite: From Manufacturing to Performance

  • Mauricio Torres,
  • Ana V. Rentería-Rodríguez,
  • Edgar A. Franco-Urquiza

DOI
https://doi.org/10.3390/chemistry4020028
Journal volume & issue
Vol. 4, no. 2
pp. 380 – 392

Abstract

Read online

This work reports the in situ instrumentation from manufacturing to loading of a henequen fiber woven-bioepoxy composite. Continuous monitoring was performed by means of fiber Bragg gratings (FBG) with the aim of tracking the curing behavior of the biolaminate by vacuum-assisted resin infusion (VARI). The instrumented composite was later tested mechanically under bending. Among the results obtained, micro-deformations were detected as a consequence of curing residual stresses, and when tested, the FBG data had similarity with the strain calculated according to the ASTM D7264/D7264M standard.