Alexandria Engineering Journal (Nov 2024)

Load frequency control in power systems with high renewable energy penetration: A strategy employing PIλ(1+PDF) controller, hybrid energy storage, and IPFC-FACTS

  • Irfan Ahmed Khan,
  • Hazlie Mokhlis,
  • Nurulafiqah Nadzirah Mansor,
  • Hazlee Azil Illias,
  • Amil Daraz,
  • A.K. Ramasamy,
  • Marayati Marsadek,
  • Abdul Rahman Afzal

Journal volume & issue
Vol. 106
pp. 337 – 366

Abstract

Read online

The high penetration of Renewable Energy Sources (RESs) in the modern power system poses a challenge to power system stability. This stability is affected by the stochastic, fluctuating output of RESs, which is influenced by weather conditions, and a lack of inertia resulting from reduced rotating mass. To address this issue, a new controller, referred to as Proportional-Fractional Integrator Plus Proportional-Derivative with Filter, PIλ(1+PDF), is designed for Load Frequency Control (LFC) with the support of a Hybrid Energy Storage System (HESS) for power systems with high-RES penetration. The HESS comprises a Superconducting Magnetic Energy Storage System (SMES) and a Vanadium Redox Flow Battery (VRFB) coupled with an Interline Power Flow Controller Flexible AC Transmission Systems (IPFC-FACTs) controller. The HESS, working in conjunction with the proposed LFC, injects virtual inertia and maintains power flow to expedite the frequency stability process. These systems are also integrated with Alternating Current (AC) and High Voltage Direct Current (HVDC) transmission lines to collectively enhance both the system's stability and the capacity of its transmission lines. To optimize the PIλ(1+PDF) controller parameters, Zebra Optimization Algorithm (ZOA) is employed utilizing an Integral Time Absolute Error (ITAE) objective function. The proposed controller is tested on a four-area power system integrated with a wind turbine, photovoltaic (PV) panels, a biodiesel generator, and a hydrogen aqua electrolyzer fuel cell, representing a high penetration of RESs in modern power systems. The results are compared with those obtained using Proportional-Integral-Derivative (PID) and Fractional Order Proportional Integral Derivative (FOPID) controllers. Sensitivity analysis and robustness tests are also performed to verify the stability of the power network by changing system parameters and under randomly chosen loading conditions. The proposed PIλ(1+PDF) controller tuned with ZOA outperforms PID and FOPID controllers by minimizing settling time for frequency changes by 62 %, eliminating overshoot, and reducing undershoots for frequency and tie-line power changes by 73 % and 55 %, respectively. Simulation results demonstrate that the proposed controller outperforms PID and FOPID controllers by effectively damping frequency and tie-line deviations, resulting in reduced frequency overshoots, undershoots, and shorter settling times.

Keywords