BMJ Paediatrics Open (Dec 2023)

Parental detection of neonatal jaundice using a low-cost colour card: a multicentre prospective study

  • Yong Zhang,
  • Qi Jiang,
  • Yuan Yuan,
  • Yi Zhao,
  • Na Chen,
  • Yawen Li,
  • Hui Peng,
  • Junping Liu,
  • Yanli Li,
  • Jing Wei,
  • Fu Xiong,
  • Huimin Zhang,
  • Yanhong Liu,
  • Guochang Xue,
  • Huali Zhang,
  • Xuexing Ding,
  • Changlin Wang,
  • Huili Yan,
  • Mingxing Ren,
  • Chaoying Ma,
  • Hanming Lu,
  • Ruifeng Meng,
  • Lingjun Xie,
  • Xiufang Cheng,
  • Jiaojiao Wang,
  • Xiaohong Xin,
  • Ruifen Wang,
  • Guijuan Liang,
  • Yuanzheng Li,
  • Jianing Kang,
  • Yinying Zhang,
  • Yinglin Su,
  • Shengjie Duan,
  • Qingsheng Liu

DOI
https://doi.org/10.1136/bmjpo-2023-001924
Journal volume & issue
Vol. 7, no. 1

Abstract

Read online

Background Since most infants are usually discharged before age 48–72 hours, peak bilirubin levels will almost always occur after discharge. Parents may be the first to observe the onset of jaundice after discharge, but visual assessment is unreliable. The jaundice colour card (JCard) is a low-cost icterometer designed for the assessment of neonatal jaundice. The objective of this study was to evaluate parental use of JCard to detect jaundice in neonates.Methods We conducted a multicentre, prospective, observational cohort study in nine sites across China. A total of 1161 newborns ≥35 weeks of gestation were enrolled in the study. Measurements of total serum bilirubin (TSB) levels were based on clinical indications. The JCard measurements by parents and paediatricians were compared with the TSB.Results JCard values of parents and paediatricians were correlated with TSB (r=0.754 and 0.788, respectively). The parents’ and paediatricians’ JCard values 9 had sensitivities of 95.2% vs 97.6% and specificities of 84.5% vs 71.7% for identifying neonates with TSB ≥153.9 µmol/L. The parents’ and paediatricians’ JCard values 15 had sensitivities of 79.9% vs 89.0% and specificities of 66.7% vs 64.9% for identifying neonates with TSB ≥256.5 µmol/L. Areas under the receiver operating characteristic curves of parents for identifying TSB ≥119.7, ≥153.9, ≥205.2, and ≥256.5 µmol/L were 0.967, 0.960, 0.915, and 0.813, respectively, and those of paediatricians were 0.966, 0.961, 0.926 and 0.840, respectively. The intraclass correlation coefficient was 0.933 between parents and paediatricians.Conclusion The JCard can be used to classify different levels of bilirubin, but it is less accurate with high bilirubin levels. The JCard diagnostic performance of parents was slightly lower than that of paediatricians.