Challenging Glass Conference Proceedings (Sep 2020)
GS&E journal > Mechanical analysis and characterization of IGUs with different silicone sealed spacer connections - Part 1: experiments
Abstract
Due to several advantages, insulated glass units (IGUs) are largely used in buildings to realize curtain walls, vertical partitions but also roofs or pedestrian systems. The typical IGU consists of two glass layers, either monolithic and/or laminated sections, that can mechanically interact via an hermetically-sealed air (or gas) cavity between them. As known, load sharing phenomena have a crucial effect on the actual mechanical response of a given IGU. Accordingly, simplified analytical methods are available in the literature to account for these load sharing effects. The existing approaches, however, assume that the spacers providing the mechanical connection along the edges of glass panels are infinitely rigid. In this paper, original experimental tests are proposed for IGU specimens characterized by the presence of different types of spacer connections, as obtained from on a selection of configurations of technical interest. The actual mechanical contribution of spacer components is then investigated, giving evidence of major findings from small-scale shear and IGU four-point bending tests. Based on comparative test observations, the edge connection efficiency is then assessed for the investigated configurations.