E3S Web of Conferences (Jan 2019)
Computer model of the power system with inclusion of a heat pump in the process of separation
Abstract
The results of computer simulation of industrial processes of separation of substances with the inclusion of a heat pump are presented. Designs of heat pumps of closed type, open type, like “pipe in pipe” are considered. In the simulation software Aspen HYSYS, the adequacy of the computer model of the “rectification unit – closed type heat pump” system was checked. The results of computer simulation of the “rectification unit – open-type heat pump ’pipe in pipe’” system are presented. This system allows to increase the efficiency of the unit by 9% compared with the system of separation of substances with the inclusion of an open-type heat pump and by 14% compared with a system with the inclusion of a closed-type heat pump.