Energies (May 2023)

Long-Term Self-Discharge Measurements and Modelling for Various Cell Types and Cell Potentials

  • Mohamed Azzam,
  • Moritz Ehrensberger,
  • Reinhard Scheuer,
  • Christian Endisch,
  • Meinert Lewerenz

DOI
https://doi.org/10.3390/en16093889
Journal volume & issue
Vol. 16, no. 9
p. 3889

Abstract

Read online

Self-discharge of lithium-ion cells leads to voltage decay over time. In this work, the self-discharge was measured at 30 ∘C for three cell types at various voltage levels for about 150 days in a constant voltage mode determining the current at a high precision (float current). All cells exhibit a transient part leading to a steady-state, which is no longer influenced by reversible effects. To study the effect of the check-ups on the steady-state float current, the cells, interrupted and not interrupted by check-ups, were compared. The results indicate that both the transient processes and steady-state currents are highly reproducible. In the first period of the float current, the polarization dominates the measured current, followed by the anode overhang effect dominating the process for a period of 5–30 days. After the decline of both processes, a mostly constant steady-state in the order of μA is observed. The check-up interruption generally shows no apparent effect on the reached steady-state and results only in an extended settling time. A model to simulate the transient process and steady-state of float currents was developed. The model shows a high accuracy in reproducing the results and identifying the time needed to reach the steady-state.

Keywords