PLoS ONE (Jan 2020)

Different classes of videoscopes and direct laryngoscopes for double-lumen tube intubation in thoracic surgery: A systematic review and network meta-analysis.

  • Young Sung Kim,
  • Jihyun Song,
  • Byung Gun Lim,
  • Il Ok Lee,
  • Young Ju Won

DOI
https://doi.org/10.1371/journal.pone.0238060
Journal volume & issue
Vol. 15, no. 8
p. e0238060

Abstract

Read online

BackgroundDouble-lumen tube is commonly used in thoracic surgeries that need one-lung ventilation, but its big size and stiff structure make it harder to perform intubation than a conventional tracheal intubation tube.ObjectivesTo investigate the effectiveness and safety of videoscopes for double-lumen tube insertion. The primary outcome was the success rate of first attempt intubation. Secondary outcomes were intubation time, malposition, oral mucosal damage, sore throat, and external manipulation.DesignSystematic review and network meta-analysis.Data sourcesDatabases (Pubmed, Embase, Cochrane, Kmbase, Web of science, Scopus) up to June 23, 2020 were searched.EligibilityRandomized controlled trials comparing different videoscopes for double-lumen tube intubation were included in this study.MethodsWe classified and lumped the videoscope devices into the following groups: standard (non-channeled) videolaryngoscope, channeled videolaryngoscope, videostylet, and direct laryngoscope. After assessing the quality of evidence, we statistically analyzed and chose the best device based on the surface under the cumulative ranking curve (SUCRA) by using STATA software (version 16).ResultsWe included 23 studies (2012 patients). Based on the success rate of the first attempt, a rankogram suggested that the standard videolaryngoscope (76.4 of SUCRA) was the best choice, followed by videostylet (65.5), channeled videolaryngoscope (36.1), and direct laryngoscope (22.1), respectively. However, with regard to reducing the intubation time, the best choice was videostylet, followed by a direct laryngoscope, channeled videolaryngoscope, and standard videolaryngoscope, respectively. Direct laryngoscope showed the lowest incidence of malposition but required external manipulation the most. Channeled videolaryngoscope showed the highest incidence of oral mucosal damage, but showed the lower incidence of sore throat than standard videolaryngoscope or direct laryngoscope.ConclusionMost videoscopes improved the success rate of double-lumen tube intubation; however, they were time-consuming (except videostylet) and had a higher malposition rate than the direct laryngoscope.