Scientific Reports (Jul 2024)
Single-position oblique lumbar interbody fusion with navigation: improved efficiency and screw accuracy compared to dual-position with fluoroscopy
Abstract
Abstract Dual-position oblique lumbar interbody fusion with fluoroscopy (D-OLIF) requires repositioning the patient to a prone position for pedicle screw insertion. Recently, single-position surgery with navigation has been introduced. However, there are concerns regarding pedicle screw accuracy and achieving appropriate sagittal balance in single-position OLIF with navigation (S-OLIF). The purpose of this study is to evaluate the clinical and radiological outcomes of S-OLIF compared to D-OLIF. A retrospective analysis was conducted on 102 patients who underwent single-level OLIF at a single institution. The patients were divided into two groups: 55 in the S-OLIF group and 47 in the D-OLIF group. The numeric rating scale for back and leg, Oswestry disability index, and walking distance improvements showed no significant difference. However, the EuroQol 5-dimension 5-level index showed higher improvement in the S-OLIF (P = 0.029). The segmental lordosis, lumbar lordosis, and C7 sagittal vertical axis showed no significant difference. S-OLIF had significantly fewer cases of pedicle screw malposition (P = 0.045). Additionally, the surgery time was shorter in the S-OLIF (P = 0.002). In conclusion, S-OLIF exhibited clinical and radiological outcomes comparable to D-OLIF, with the added advantages of reduced surgery time and enhanced accuracy in pedicle screw placement.