Ingeniería e Investigación (Jun 2011)

Operational analysis of electric field mills as lightning warning systems in Colombia

  • D. Aranguren,
  • J. López,
  • E. Pérez,
  • J. Herrera,
  • L. Aragón,
  • H. Torres

Journal volume & issue
Vol. 31, no. 2SUP
pp. 51 – 57

Abstract

Read online

Electrostatic field measurements taken in Bogotá, Colombia, during thunderstorms in November (the rainy season due to inter-tropical confluence zone over central Colombia) were used to study the performance of an isolated electric field sensor and analyse its most important operational characteristics. The distances from each flash to the studied sensor were obtained by using the Colombian lightning location system. The DE cf distance ratio led to defining a charge model which could be used as a reference for calibrating other electrostatic field sensors to be used as lightning warning systems.

Keywords