Materials (Nov 2023)

Testing Various Cement Formulations under Temperature Cycles and Drying Shrinkage for Low-Temperature Geothermal Wells

  • Hartmut R. Fischer,
  • Al Moghadam

DOI
https://doi.org/10.3390/ma16237281
Journal volume & issue
Vol. 16, no. 23
p. 7281

Abstract

Read online

Low-enthalpy geothermal wells are considered a sustainable energy source, particularly for district heating in the Netherlands. The cement sheath in these wells experiences thermal cycles. The stability of cement recipes under such conditions is not well understood. In this work, thermal cycling experiments for intermediate- and low-temperature geothermal well cements have been conducted. The samples were cured either under ambient conditions or under realistic pressure and temperature for 7 days. The samples did not show any signs of failure after performing 10 cycles of thermal treatment between 100 °C and 18 °C. We also tested cement formulations under drying conditions. Drying shrinkage is caused by a reduction in the water content of cement, which leads to capillary forces that can damage cement. Such circumstances lead to tensile stresses causing radial cracks. Most samples exhibited cracks under low humidity conditions (drying). Fiber reinforcement, especially using short PP fibers, improved the cement’s resilience to temperature and humidity changes. Such additives can improve the longevity of cement sheaths in geothermal wells.

Keywords