Stroke: Vascular and Interventional Neurology (Nov 2021)
Abstract 1122‐000142: Safety and Efficacy of Surpass Streamline for Intracranial Aneurysms: A Multicenter US Real‐World Experience (SESSIA)
Abstract
Introduction: Flow diversion has established itself as standard treatment of wide complex intracranial aneurysms (IA). Its recognition has been validated with positive occlusion rates and favorable clinical outcomes. The Surpass Streamline (SS) flow diverter (FD) is a braided cobalt/chromium alloy implant with 72 or 96 wires approved by the FDA in 2018. The aim of this study is to determine the safety and efficacy of the SS in a post‐marketing large US cohort. Methods: We performed a multicenter, retrospective study for consecutive patients treated with the SS FD for IA between January 2018 and June 2021 in the United States. Inclusion criteria for participants were: 1. Adults (≥ 18 years) and 2. Treatment with SS FD for IA. Primary safety end point was a major ipsilateral stroke (increase in National Institutes of Health Stroke Scale Score of ≥ 4) or neurological death within 12 months. Primary efficacy was assessed using the 3‐point Raymond‐Roy (RR) occlusion scale on digital subtraction angiography (DSA) at 6‐12‐month follow‐up. Results: A total of 276 patients with 313 aneurysms were enrolled. The median age was 59 years and 199 (72%) were females. The most common comorbidities included hypertension in 156 (57%) subjects followed by hyperlipidemia in 76 (28%) patients. One hundred and twenty‐two (44%) patients were asymptomatic while subarachnoid hemorrhage was present in only 10 (4%) patients. A total of 143 (46%) aneurysms were left‐sided. Aneurysms were located as follows: 274 (88%) were in the anterior circulation with paraophthalmic being the most common in 120 (38%) followed by petrocavernous ICA in 81 (26%); 33 (11%) aneurysms were located in the posterior circulation with basilar trunk being the most common in 14 (5%). The mean maximum aneurysm dome width was 5.77 ± 4.7 mm, neck width 4.22 ± 3.8 mm and dome to neck ratio was 1.63 ± 1.3 mm. The mean number of SS FD implanted per aneurysm was 1.06 (range 1–3) with more than one SS FD implanted in 21 (7%) aneurysms. Modified Rankin Scale (mRS) of 0–2 was present in 206/213 (97%) patients at 6–12 month follow‐up. The complete aneurysm occlusion (RR 1) rate was 145/175 (83%) among subjects who had angiographic follow‐up at 6–12 months. Major stroke and death was encountered in 7 (2%) and 5 (1.8%) of the patients respectively. Conclusions: Our data represent the largest real‐world study using SS FD. These results corroborate its post‐marketing safety and efficacy for the treatment of intracranial aneurysms showing more favorable rates to the initial experience during SCENT trial.
Keywords