The Journal of Engineering (May 2019)
Performance of superconducting generators with different topologies under fault conditions
Abstract
This paper compares the short-circuit performance of superconducting (SC) generators with three different topologies, i.e. iron-cored stator and rotor, iron-cored stator and air-cored rotor, and air-cored stator and rotor. The analysis is based on three-phase short-circuit fault, and finite element analysis is used for simulation. Following the introduction of specifications of generators, the short-circuit performances of different topologies are analysed and compared, with the field winding excited by voltage and current excitation sources, respectively. It shows that the short-circuit performance can be improved by limiting the field current.
Keywords