Metals (Jun 2019)
The Auto-Correlation of Ultrasonic Lamb Wave Phased Array Data for Damage Detection
Abstract
Ultrasonic phased array is widely used for damage detection recently because of its high sensitivity and rapid scanning without sensor movements. However, the measured signal is always influenced by the remnants of the initial excitation and the nonlinear signals from the instrumentation, which limits its application in thin-plate structures. To address this issue, an approach called auto-correlation subtraction is proposed to extract the scattering information of defects in this paper. In order to testify the feasibility of this method for damage detection, the experiments were carried out on three thin aluminum plates combined with the total focusing method (TFM) for imaging. By auto-correlating the full matrix data received by sensors and then subtracting the average auto-correlation of noise recorded by all receivers, the coherent scattered signal containing defect information is recovered. The experimental results indicate that the coherent travel time is in agreement with the theoretical value and the signal-to-noise ratio are improved. Additionally, compared with the cross-correlation technique, the time synchronization between different receivers is not necessary with the auto-correlation method. Results indicate that the presented method can improve the imaging resolution and has a great potential in the field of non-destructive testing.
Keywords