International Journal of Distributed Sensor Networks (Jan 2016)
Errors Nature of the Narrowband PLC Transmission in Smart Lighting LV Network
Abstract
This paper presents characteristics of the Frame Error Rate versus Signal to Noise Ratio obtained from Smart Lighting LV network. These characteristics are the results of carrying out many field-trials in three locations. During the one-year tests period lighting systems evolved from the traditional, gas-discharge not individually dimmable system to LED or gas-discharge Smart Lighting system controlled with the use of PLC technology every lamp individually. A different influence of the frame length on the F E R ( S N R ) characteristic for the gas-discharge and LED LV networks led to examining the bit errors distribution. The bit errors distribution characteristics of the narrowband PLC transmission over the Smart Metering LV network are also presented in this paper. All the presented data in this work are the results of the long time field-trials, which were verified in the lab conditions.