Brazilian Journal of Radiation Sciences (Jul 2021)

Small break loss of coolant accident of 200 cm² in cold leg of primary loop of Angra2 nuclear power reactor evaluation

  • EDUARDO MADEIRA BORGES,
  • GAIANÊ SABUNDJIAN

DOI
https://doi.org/10.15392/bjrs.v9i2B.1274
Journal volume & issue
Vol. 9, no. 2B

Abstract

Read online

The aim of this paper is evaluated the consequences to ANGRA 2 nuclear power reactor and to identify the flow regimes, the heat transfer modes, and the correlations used by RELAP5/MOD3.2.gama code in ANGRA 2 during the Small-Break Loss-of-Coolant Accident (SBLOCA) with a 200cm2 of rupture area in the cold leg of primary loop. The Chapter 15 of the Final Safety Analysis Report of ANGRA 2 (FSAR-A2) reports this specific kind of accident. The results from this work demonstrated the several flow regimes and heat transfer modes that can be present in the core of ANGRA 2 during the postulated accident. The results obtained for ANGRA 2 nuclear reactor core during the postulated accident were satisfactory when compared with the FSAR-A2. Additionally, the results showed the correct actuation of the ECCS guaranteeing the integrity of the reactor core.

Keywords