Journal of the Egyptian National Cancer Institute (Sep 2021)
A retrospective comparison of two different immobilization systems for radiotherapy of extremity soft tissue sarcomas and its influence on CTV-PTV margin
Abstract
Abstract Background On account of extremity wide range of movements and difficulty of reproducibility during irradiation of extremity sarcomas, assorted immobilization strategies are employed to eliminate setup errors. The study purpose was to compare the setup errors of the commonly used immobilization tools and to define planning target volume (PTV) margins for each device. Methods A retrospective review comparing Vac-Loc™ and thermoplastic cast (Tcast) was conducted. On radiotherapy treatment, portal imaging was matched with the pre-treatment simulation imaging for both fixation tools. The isocenter shifts and total vector error (TVE) were compared. Random (σ) and systemic errors (Σ) were computed and PTV margins were defined. Results Three hundred seven shifts in each direction measured in 14 patients. Mean displacements for the Vac-Loc™ and Tcast, respectively, were as follow: vertical; -0.01 cm vs. 0.02 cm, longitudinal; 0.03 cm vs. 0.04; lateral; 0.04 cm vs. 0.00 cm and TVE; 0.15 cm vs. 0.17 cm with no significant statistical difference. Random and systemic errors were comparable for both devices. The lateral displacement and rotational random errors were higher Vac-Loc™ compared to Tcast. Overall measured PTV margins were marginally lower for Tcast compared to Vac-Loc™. Conclusion Vac-Loc™ and Tcast are valid options for immobilization with no clear superiority of either device. The marginal advantage of Tcast warrants further prospective studies.