Practical Laboratory Medicine (Apr 2015)
Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0Â ng/mL to 13.0Â ng/mL
Abstract
Objective: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. Methods: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a) evidence of corrective action in patients with serum folate values 25.7 ng/mL. Results: The prevalence of serum folate levels, in patients, 25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate 60% of the patients. Since serum folate levels â¥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be â¥13.0 ng/mL. Keywords: Serum folate, Prevalence of folate deficiency, Neural tube defects, Optimum serum folate level, Utility of folate testing