The Egyptian Journal of Bronchology (Jan 2020)

Comparison between cryobiopsy and forceps biopsy in detection of epidermal growth factor receptor amplification in non-small-cell lung cancer

  • Ahmed S. H. Mohamed,
  • Mohamed Hantera,
  • Ragia S. Sharshar,
  • Amira Y. Abdelnaby,
  • Ayman El Saka

DOI
https://doi.org/10.4103/ejb.ejb_40_19
Journal volume & issue
Vol. 13, no. 5
pp. 636 – 643

Abstract

Read online

Abstract Background Non-small-cell lung cancer (NSCLC) represents 85% of lung cancer cases. Genotyping is now considered as a cornerstone in proper management and better results of such cancers, especially with targeted therapy. Cryobiopsy is a promising tool in NSCLC to obtain larger samples, with well-preserved tissue sufficient for accurate histopathological and gene detection. Aim To compare cryobiopsy and ordinary forceps results in detection of epidermal growth factor receptor (EGFR) amplification in NSCLC. Materials and methods Samples from 34 patients with proven NSCLC by cryobiopsy versus forceps biopsy were compared for size, quality, and diagnostic yield of EGFR gene amplification. Results The samples obtained by cryoprobe had larger size and better artifact-free areas with more diagnostic yield of EGFR gene amplification (29.4%) versus with forceps biopsy (8.8%), with gene amplification showing higher statistical significance in younger patients, never smokers, and women (P<0.001). Conclusion Cryobiopsy is an excellent tool for larger, better-quality sampling and for higher diagnostic yield of EGFR amplification in NSCLC.

Keywords