Brazilian Oral Research (Aug 2014)

Degradation of orthodontic wires under simulated cariogenic and erosive conditions

  • Laura Cavalcante Lima JABER,
  • José Augusto RODRIGUES,
  • Flávia Lucisano Botelho AMARAL,
  • Fabiana Mantovani Gomes FRANÇA,
  • Roberta Tarkany BASTING,
  • Cecilia Pedroso TURSSI

DOI
https://doi.org/10.1590/1807-3107BOR-2014.vol28.0024
Journal volume & issue
Vol. 28, no. 1
pp. 1 – 6

Abstract

Read online

This study examined the effect of cariogenic and erosive challenges (CCs and ECs, respectively) on the degradation of copper-nickel-titanium (CuNiTi) orthodontic wires. Sixty wire segments were divided into four treatment groups and exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control). CC and EC were simulated using a demineralizing solution (pH 4.3) and a citric acid solution (pH 2.3), respectively. Following treatment, the average surface roughness (Ra) of the wires was assessed, and friction between the wires and a passive self-ligating bracket was measured. CuNiTi wires subjected to ECs exhibited significantly higher Ra values than did those that were stored in artificial saliva. In contrast, surface roughness was not affected by CCs. Finally, friction between the treated wires and brackets was not affected by ECs or CCs. Our results indicate that CuNiTi orthodontic wires may suffer degradation within the oral cavity, as ECs increased the surface roughness of these wires. However, rougher surfaces did not increase friction between the wire and the passive self-ligating bracket.

Keywords