Arquivos Brasileiros de Cardiologia ()

Sensitive Troponin I Assay in Patients with Chest Pain - Association with Significant Coronary Lesions with or Without Renal Failure

  • Alexandre de Matos Soeiro,
  • Danielle Menosi Gualandro,
  • Aline Siqueira Bossa,
  • Cindel Nogueira Zullino,
  • Bruno Biselli,
  • Maria Carolina Feres de Almeida Soeiro,
  • Tatiana de Carvalho Andreucci Torres Leal,
  • Carlos Vicente Serrano Jr.,
  • Mucio Tavares de Oliveira Junior

DOI
https://doi.org/10.5935/abc.20170182
Journal volume & issue
Vol. 110, no. 1
pp. 68 – 73

Abstract

Read online

Abstract Introduction: Despite having higher sensitivity as compared to conventional troponins, sensitive troponins have lower specificity, mainly in patients with renal failure. Objective: Study aimed at assessing the sensitive troponin I levels in patients with chest pain, and relating them to the existence of significant coronary lesions. Methods: Retrospective, single-center, observational. This study included 991 patients divided into two groups: with (N = 681) and without (N = 310) significant coronary lesion. For posterior analysis, the patients were divided into two other groups: with (N = 184) and without (N = 807) chronic renal failure. The commercial ADVIA Centaur® TnI-Ultra assay (Siemens Healthcare Diagnostics) was used. The ROC curve analysis was performed to identify the sensitivity and specificity of the best cutoff point of troponin as a discriminator of the probability of significant coronary lesion. The associations were considered significant when p < 0.05. Results: The median age was 63 years, and 52% of the patients were of the male sex. The area under the ROC curve between the troponin levels and significant coronary lesions was 0.685 (95% CI: 0.65 - 0.72). In patients with or without renal failure, the areas under the ROC curve were 0.703 (95% CI: 0.66 - 0.74) and 0.608 (95% CI: 0.52 - 0.70), respectively. The best cutoff points to discriminate the presence of significant coronary lesion were: in the general population, 0.605 ng/dL (sensitivity, 63.4%; specificity, 67%); in patients without renal failure, 0.605 ng/dL (sensitivity, 62.7%; specificity, 71%); and in patients with chronic renal failure, 0.515 ng/dL (sensitivity, 80.6%; specificity, 42%). Conclusion: In patients with chest pain, sensitive troponin I showed a good correlation with significant coronary lesions when its level was greater than 0.605 ng/dL. In patients with chronic renal failure, a significant decrease in specificity was observed in the correlation of troponin levels and severe coronary lesions.

Keywords