Acta Cirúrgica Brasileira (Feb 2017)

Comparative study of Polypropylene versus Parietex composite®, Vicryl® and Ultrapro® meshes, regarding the formation of intraperitoneal adhesions

  • Maria de Lourdes Pessole Biondo-Simões,
  • Laísa Brandão Carvalho,
  • Lucas Tavares Conceição,
  • Kassyane Bordignon Piccinelli dos Santos,
  • Wagner Augusto Schiel,
  • Mayara Arantes,
  • Tatiane da Silveira,
  • Júlio César Magri,
  • Fernanda Fabrini Gomes

DOI
https://doi.org/10.1590/s0102-865020170202
Journal volume & issue
Vol. 32, no. 2
pp. 98 – 107

Abstract

Read online Read online

Abstract Purpose: To compare the polypropylene mesh (Marlex®) to Vicryl®, Parietex composite® and Ultrapro® meshes to assess the occurrence of adhesions in the intraperitoneal implantation. Methods: Sixty Wistar rats were allocated into three groups: PP+V, in which all the animals received a polypropylene and a Vicryl® mesh; PP+PC, with the implantation of polypropylene and Parietex composite® meshes and PP+UP, in which there was implantation of polypropylene and Ultrapro®. Macroscopic analysis was performed 28 days later to assess the percentage of mesh area affected by adhesion. Results: in the PP+ V group, the Vicryl® mesh showed lower adhesion formation (p=0.013). In the PP+PC, there were no differences between polypropylene and Parietex composite® (p=0.765). In the PP+UP group, Ultrapro® and polypropylene meshes were equivalent (p=0.198) . Conclusion: All the four meshes led to adhesions, with the Vicryl® mesh showing the least potential for its formation.