Radiation Oncology (May 2021)

Benefit of replanning in MR-guided online adaptive radiation therapy in the treatment of liver metastasis

  • Michael Mayinger,
  • Roman Ludwig,
  • Sebastian M. Christ,
  • Riccardo Dal Bello,
  • Alex Ryu,
  • Nienke Weitkamp,
  • Matea Pavic,
  • Helena Garcia Schüler,
  • Lotte Wilke,
  • Matthias Guckenberger,
  • Jan Unkelbach,
  • Stephanie Tanadini-Lang,
  • Nicolaus Andratschke

DOI
https://doi.org/10.1186/s13014-021-01813-6
Journal volume & issue
Vol. 16, no. 1
pp. 1 – 8

Abstract

Read online

Abstract Purpose To assess the effects of daily adaptive MR-guided replanning in stereotactic body radiation therapy (SBRT) of liver metastases based on a patient individual longitudinal dosimetric analysis. Methods Fifteen patients assigned to SBRT for oligometastatic liver metastases underwent daily MR-guided target localization and on-table treatment plan re-optimization. Gross tumor volume (GTV) and organs at risk (OARs) were adapted to the anatomy-of-the-day. A reoptimized plan (RP) and a rigidly shifted baseline plan (sBP) without re-optimization were generated for each fraction. After extraction of DVH parameters for GTV, planning target volume (PTV), and OARs (stomach, duodenum, bowel, liver, heart) plans were compared on a per-patient basis. Results Median pre-treatment GTV and PTV were 14.9 cc (interquartile range (IQR): 7.7–32.9) and 62.7 cc (IQR: 42.4–105.5) respectively. SBRT with RP improved PTV coverage (V100%) for 47/75 of the fractions and reduced doses to the most proximal OARs (D1cc, Dmean) in 33/75 fractions compared to sBP. RP significantly improved PTV coverage (V100%) for metastases within close proximity to an OAR by 4.0% (≤ 0.2 cm distance from the edge of the PTV to the edge of the OAR; n = 7; p = 0.01), but only by 0.2% for metastases farther away from OAR (> 2 cm distance; n = 7; p = 0.37). No acute grade 3 treatment-related toxicities were observed. Conclusions MR-guided online replanning SBRT improved target coverage and OAR sparing for liver metastases with a distance from the edge of the PTV to the nearest luminal OAR < 2 cm. Only marginal improvements in target coverage were observed for target distant to critical OARs, indicating that these patients do not benefit from daily adaptive replanning.