Journal of Orthopaedic Translation (Oct 2018)

Biomechanical properties of novel transpedicular transdiscal screw fixation with interbody arthrodesis technique in lumbar spine: A finite element study

  • Qing-Bo Lv,
  • Xiang Gao,
  • Xiang-Xiang Pan,
  • Hai-Ming Jin,
  • Xiao-Ting Lou,
  • Shu-Min Li,
  • Ying-Zhao Yan,
  • Cong-Cong Wu,
  • Yan Lin,
  • Wen-Fei Ni,
  • Xiang-Yang Wang,
  • Ai-Min Wu

Journal volume & issue
Vol. 15
pp. 50 – 58

Abstract

Read online

Purpose: The purpose of this study was to investigate finite element biomechanical properties of the novel transpedicular transdiscal (TPTD) screw fixation with interbody arthrodesis technique in lumbar spine. Methods: An L4–L5 finite element model was established and validated. Then, two fixation models, TPTD screw system and bilateral pedicle screw system (BPSS), were established on the validated L4–L5 finite element model. The inferior surface of the L5 vertebra was set immobilised, and moment of 7.5 Nm was applied on the L4 vertebra to test the range of motion (ROM) and stress at flexion, extension, lateral bending and axial rotation. Results: The intact model was validated for prediction accuracy by comparing two previously published studies. Both of TPTD and BPSS fixation models displayed decreased motion at L4–L5. The ROMs of six moments of flexion, extension, left lateral bending, right lateral bending, left axial rotation and right axial rotation in TPTD model were 1.92, 2.12, 1.10, 1.11, 0.90 and 0.87°, respectively; in BPSS model, they were 1.48, 0.42, 0.35, 0.38, 0.74 and 0.75°, respectively. The screws' peak stress of above six moments in TPTD model was 182.58, 272.75, 133.01, 137.36, 155.48 and 150.50 MPa, respectively; and in BPSS model, it was 103.16, 129.74, 120.28, 134.62, 180.84 and 169.76 MPa, respectively. Conclusion: Both BPSS and TPTD can provide stable biomechanical properties for lumbar spine. The decreased ROM of flexion, extension and lateral bending was slightly more in BPSS model than in TPTD model, but TPTD model had similar ROM of axial rotation with BPSS model. The screws' peak stress of TPTD screw focused on the L4–L5 intervertebral space region, and more caution should be put at this site for the fatigue breakage. The translational potential of this article: Our finite element study provides the biomechanical properties of novel TPTD screw fixation, and promotes this novel transpedicular transdiscal screw fixation with interbody arthrodesis technique be used clinically. Keywords: Bilateral pedicle screw system, Biomechanics, Finite element, Lumbar arthrodesis, Transpedicular transdiscal screw