Cardiovascular Ultrasound (Dec 2004)

Echocardiographic AV-interval optimization in patients with reduced left ventricular function

  • Baumann G,
  • Combs W,
  • Richter WS,
  • Knebel F,
  • Borges AC,
  • Melzer C,
  • Theres H

DOI
https://doi.org/10.1186/1476-7120-2-30
Journal volume & issue
Vol. 2, no. 1
p. 30

Abstract

Read online

Abstract Background Ritter's method is a tool used to optimize AV delay in DDD pacemaker patients with normal left ventricular function only. The goal of our study was to evaluate Ritter's method in AV delay-interval optimization in patients with reduced left ventricular function. Methods Patients with implanted DDD pacemakers and AVB III° were assigned to one of two groups according to ejection fraction (EF): Group 1 (EF > 35%) and Group 2 (EF Results For each of the patients examined, we succeeded in defining an optimal AV interval by means of both RNV and Ritter's method. The optimal AV delay determined by RNV correlated well with the delay found by Ritter's method, especially among those patients with reduced EF. The intra-class correlation coefficient was 0.8965 in Group 1 and 0.9228 in Group 2. The optimal AV interval in Group 1 was 190 ± 28.5 ms, and 180 ± 35 ms in Group 2. Conclusion Ritter's method is also effective for optimization of AV intervals among patients with reduced left ventricular function (EF