BMC Cardiovascular Disorders (Oct 2024)

Change in left bundle branch potential-ventricular interval during lead implantation: what is the mechanism?

  • Jiabo Shen,
  • Kecheng Dai,
  • Longfu Jiang,
  • Hao Wu,
  • Hengdong Li,
  • Lifang Pan

DOI
https://doi.org/10.1186/s12872-024-04294-z
Journal volume & issue
Vol. 24, no. 1
pp. 1 – 3

Abstract

Read online

Abstract A 75-year-old male with sick sinus syndrome (SSS) underwent left bundle branch (LBB) pacing (LBBP) implantation. Intraoperative recordings showed that the LBB potential-ventricular (LBB-V) interval gradually decreased from 47 to 19 ms (ms). Two-year follow-up indicated stable pacing parameters and consistent electrocardiogram (ECG) results. Despite potential conduction delays caused by lead implantation, a watchful waiting strategy demonstrated recovery potential without impacting long-term prognosis or pacing parameters.

Keywords