IEEE Access (Jan 2020)

Dynamic Phasor Modeling of Various Multipulse Rectifiers and a VSI Fed by 18-Pulse Asymmetrical Autotransformer Rectifier Unit for Fast Transient Analysis

  • Dongsheng Yuan,
  • Shuhong Wang,
  • Yilu Liu

DOI
https://doi.org/10.1109/ACCESS.2020.2977270
Journal volume & issue
Vol. 8
pp. 43145 – 43155

Abstract

Read online

To study the fast modelling of dynamic characteristics caused by power electronic switching, the dynamic phasor (DP) theory based on the time-varying Fourier decomposition and frequency shifting is firstly applied to the modelling of various multipulse rectifiers. The DP model for symmetrical 12-pulse phase-shifting reactor rectifier unit (PSR-RU) is derived with model order reduction, relations between ac and dc terminals, and Taylor series expansion. The DP model of asymmetrical 18-pulse autotransformer rectifier unit (AT-RU) is proposed based on the switching functions expressed in the DP domain. Meanwhile, the DP model of voltage source inverter (VSI) fed by asymmetrical 18-pulse AT-RU is built with the harmonic state-space (HSS) equations. Under both balanced and unbalanced conditions, the good calculation accuracy and rapid simulation speed of the developed DP models are validated by the detailed time-domain (TD) simulation.