BMC Public Health (Aug 2020)

Cross-cultural adaptation and validation of the Global Physical Activity Questionnaire among healthy Hungarian adults

  • Pongrác Ács,
  • József Betlehem,
  • András Oláh,
  • Barbara Bergier,
  • Kata Morvay-Sey,
  • Alexandra Makai,
  • Viktória Prémusz

DOI
https://doi.org/10.1186/s12889-020-08477-z
Journal volume & issue
Vol. 20, no. S1
pp. 1 – 10

Abstract

Read online

Abstract Background Physical activity (PA) is an important factor among the determinants of health due to it’s protective factor and preventive role. Self-reported measures such as questionnaires are most commonly used in public health studies, but may over- or underestimate actual patterns of PA. Therefore, accelerometers are widely used to assess concurrent validity. The aim of the present study was to adapt and validate the self-administered GPAQ - Hungarian version (GPAQ-H) against accelerometer data and IPAQ-Hungarian long version (IPAQ-HL) in Hungarian healthy young adults. Methods A cross-sectional comparative study was conducted to examine the last 7 days PA by GPAQ-H, comparing with IPAQ-HL and Actigraph GT3X accelerometer to measure concurrent validity and reliability. A convenient sample of 300 young adults was recruited in January – July 2018 at the University of Pécs, in South-Hungary, 120 participants (age 21.53 ± 1.75 years, 46.66% male) were included in the validity and reliability study. Results Significant differences between the three instruments were found (p < 0.001) in all scores, except PAQs vigorous activities (p = 0.332) and GPAQ-H and accelerometer MVPA score (p = 0.424). A moderate KMO measure was found (0.538) with a significant Barlett’s test of Sphericity (279.51; p < 0.001). The total variance was explained as 81.10%. The reliability of the GPAQ-H instrument with all domain’s scores was 0.521 (CI 0.371–0.644). We found in all intensity scores and sitting time good reliability scores (R = 0.899–987, p < 0.001) between the baseline and follow-up (N = 33 random subsample). The Bland-Altman plots were showed that GPAQ-H overestimates vigorous activities by 212.75 min/week (331.82–757.42) and MVPA by 104.93 min/week (− 1016.98–807.11). A high difference, 6336.79 min/week (CI 3638.18–9035.40) was revealed regarding sitting, as GPAQ-H largely underestimated the time spent sedentary. Conclusions The Hungarian GPAQ self-administered form showed fair to moderate validity with correlation coefficients similar to other European studies. Based on our study’s results it could be claimed that the GPAQ-H measurement tool is a valid and reliable questionnaire to measure the healthy Hungarian population’s physical activity patterns. However, our results also proved that GPAQ-H alone is not a valid and reliable questionnaire to measure sitting time.

Keywords