Unveiling the Mysteries of the Chinese lens zonule balance tension: A statistical analysis
Lujie Zhang,
Kai Wen,
Ming Liu,
Jie Wang,
Yifang Huang,
Yufeng Zhang,
Ruihua Wei,
Jing Sun
Affiliations
Lujie Zhang
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China; Tianjin Children's Hospital, Tianjin Key Laboratory of Birth Defects for Prevention and Treatment, China
Kai Wen
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China
Ming Liu
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China
Jie Wang
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China
Yifang Huang
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China
Yufeng Zhang
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China
Ruihua Wei
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China; Corresponding author. No. 251, Fukang Road, Nankai District, Tianjin, 300110, China.
Jing Sun
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, China; Corresponding author. No. 251, Fukang Road, Nankai District, Tianjin, 300110, China .
Background: This study aims to provide an estimated dataset of lens zonule balance tension (LZBT) measurements in cataractous lenses among Chinese patients and to conduct a statistical analysis of anterior segment parameters. Methods: This is a cross-sectional study. We included a total of 833 eyes from 833 Chinese participants aged 23–91 years who underwent cataract surgery. Anterior segment parameters were measured using swept-source anterior segment optical coherence tomography (SS-AS OCT) to calculate lens gravity (LG) and crystalline lens volume (VOL). Axial length (AL) was measured using IOL-Master 700. LZBT was calculated using force decomposition and synthesis methods. Results: The mean LZBT in the horizontal direction was 8.48E-05 ± 3.23E-05 N across all eyes. The LZBT in the subtemporal-supraspinal and supraspinal-temporal directions was 2 times greater than in the vertical direction. The balanced force on the suspensory ligament in the horizontal direction was twice as strong as in the vertical direction. Additionally, anterior segment parameters such as lens equivalent diameter (LE-dia), radius of the anterior lens surface curvature (RAL), radius of the posterior lens surface curvature (RPL), anterior chamber depth (ACD), iris area, iris volume, and iris thickness showed positive correlations with AL. Conclusions: Accounting for gravitational effects, we concluded that zonule force is asymmetrically distributed. Importantly, this study establishes the normal range of LZBT across different meridians using force synthesis and decomposition, offering new insights and feasibility for studying suspensory ligament biomechanics.