Química Nova (Jan 2014)

Determination of triamterene in human plasma and urine after its cloud point extraction

  • Ahad Bavili Tabrizi,
  • Sana Naini,
  • Kosar Parnian,
  • Samin Mohammadi,
  • Fayeze Emami zad,
  • Samira Pourtaghi Anvarian,
  • Ali Abdollahi

DOI
https://doi.org/10.5935/0100-4042.20140188
Journal volume & issue
Vol. 37, no. 7
pp. 1182 – 1187

Abstract

Read online

A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.