BMC Cardiovascular Disorders (Jun 2021)

Impact of pericardial fluid glucose level and computed tomography attenuation values on diagnosis of malignancy-related pericardial effusion

  • Takashi Nakamura,
  • Mana Okune,
  • Masakazu Yasuda,
  • Heitaro Watanabe,
  • Masafumi Ueno,
  • Kenji Yamaji,
  • Kazuki Mizutani,
  • Takashi Kurita,
  • Gaku Nakazawa

DOI
https://doi.org/10.1186/s12872-021-02091-6
Journal volume & issue
Vol. 21, no. 1
pp. 1 – 10

Abstract

Read online

Abstract Background We evaluated malignancy according to the characteristics of pericardial fluid in symptomatic Japanese patients undergoing pericardiocentesis and computed tomography (CT). Methods This was a retrospective, single-center, observational study of 125 symptomatic patients undergoing pericardiocentesis. The patients were classified into two groups: a malignancy group and a non-malignancy group, according to the primary disease and cytology of the pericardial effusion (PE). We compared the pericardial fluid sample and CT measurements between both groups. Results All patients were diagnosed as having exudative PE by Light’s criteria. PE with malignant cells was demonstrated in 76.8% of the malignancy group patients. Pericardial to serum lactate dehydrogenase (LDH) ratio > 0.6, as one of Light’s criteria, was associated with malignancy (p = 0.017). Lower serum brain natriuretic peptide (BNP) concentration was also associated with malignancy (BNP: 126.9 ± 89.8 pg/ml vs 409.2 ± 97.7 pg/ml, malignancy vs non-malignancy groups, respectively; p = 0.037). A significant difference was observed in pericardial fluid glucose level between the malignancy and non-malignancy groups (pericardial fluid glucose: 78.24 ± 48.29 mg/dl vs 98.41 ± 44.85, respectively; p = 0.048). Moreover, CT attenuation values (Hounsfield units (HU)) tended to be higher in the malignancy group vs the non-malignancy group (22.7 [interquartile range (IQR), 17.4–26.0] vs 17.4 [IQR, 13.7–26.4], respectively; p = 0.08). The sensitivity and specificity of pericardial fluid glucose level ≤ 70 mg/dl and CT attenuation values > 20 HU were 40.9% and 89.6%, respectively, in the malignancy group. The positive- and negative predictive values of pericardial fluid glucose level ≤ 70 mg/dl and CT attenuation values > 20 HU were 85.7% and 50.0%, respectively, in the malignancy group. Pericardial fluid glucose level ≤ 70 mg/dl and CT attenuation values > 20 HU were cutoff values associated with malignancy (p = 0.012). Conclusions Lower pericardial fluid glucose level with higher CT attenuation values may suggest malignancy-related PE.

Keywords