PLoS ONE (Jan 2022)

Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation.

  • Lachlan F Miles,
  • Etienne J Couture,
  • Cristhian Potes,
  • Timothy Makar,
  • Malindra C Fernando,
  • Akshay Hungenahally,
  • Matthew D Mathieson,
  • Hannah Perlman,
  • Marcos V Perini,
  • Dilraj Thind,
  • Laurence Weinberg,
  • André Y Denault

DOI
https://doi.org/10.1371/journal.pone.0263386
Journal volume & issue
Vol. 17, no. 2
p. e0263386

Abstract

Read online

BackgroundDespite increasing attention in the cardiac anesthesiology literature, continuous measurement of right ventricular pressure using a pulmonary artery catheter has not been described in orthotopic liver transplantation, despite similarities in the anesthetic approach to the two populations. We describe our preliminary experience with this technique in orthotopic liver transplantation, and by combining various derived measures with trans-esophageal echocardiography, make some early observations regarding the response of these measures of right ventricular function during the procedure.MethodsIn this case series, ten patients (five men and five women) undergoing orthotopic liver transplantation in our institution had their surgeries performed while monitored with a pulmonary artery catheter with continuous right ventricular port transduction and trans-esophageal echocardiography. We recorded various right ventricular waveform (early-to-end diastolic pressure difference, right ventricular outflow tract gradient, right ventricular dP/dT and right ventricular end-diastolic pressure) and echocardiographic (right ventricular fractional area change, tricuspid annular plane systolic excursion, right ventricular lateral wall strain) and described their change relative to baseline at timepoints five minutes before and after portal vein reperfusion, immediately after hepatic artery reperfusion and on abdominal closure.ResultsExcept for tricuspid annular plane systolic excursion at five minutes prior to reperfusion (mean -0.8 cm; 95% CI-1.4, -0.3; p = 0.007), no echocardiographic metric was statistically significantly different at any timepoint relative to baseline. In contrast, changes in right ventricular outflow tract gradient and right ventricular dP/dt were highly significant at multiple timepoints, generally peaking immediately before or after reperfusion before reducing, but not returning to baseline in the neohepatic phase. Nine of 10 participants in this series demonstrated a degree of dynamic right ventricular outflow tract obstruction, which met criteria for hemodynamic significance (> 25 mmHg) in two participants. These changes were not materially affected by cardiac index.ConclusionsDynamic right ventricular outflow tract obstruction of varying severity appears common in patients undergoing orthotopic liver transplantation. These results are hypothesis generating and will form the basis of future prospective research.