Energies (Mar 2020)

Numerical Study of the Winter–Kennedy Flow Measurement Method in Transient Flows

  • Binaya Baidar,
  • Jonathan Nicolle,
  • Bhupendra K. Gandhi,
  • Michel J. Cervantes

DOI
https://doi.org/10.3390/en13061310
Journal volume & issue
Vol. 13, no. 6
p. 1310

Abstract

Read online

This paper explores the possibility of using the Winter−Kennedy (WK) method for transient flow rate measurement in hydraulic turbines. Computational fluid dynamic (CFD) analysis of a numerical model of an axial turbine was carried out for accelerating and decelerating flows. Those were obtained by linearly opening and closing of the guide vanes, respectively, while retaining the inlet pressure constant during the simulations. The behavior of several WK configurations on a cross-sectional plane and along the azimuthal direction of the spiral casing was studied during the transients. The study showed that there are certain WK configurations that are more stable than others. The physical mechanism behind the stability (or instability) of the WK method during transients is presented. Using the steady WK coefficient obtained at the best efficiency point (BEP), the WK method could estimate the transient flow rate with a deviation of about 7.5% and 3.5%, for accelerating and decelerating flow, respectively.

Keywords