Defence Technology (Aug 2020)

Experimental investigation on dynamic response and damage models of circular RC columns subjected to underwater explosions

  • Tie-shuan Zhuang,
  • Ming-yang Wang,
  • Jun Wu,
  • Cheng-yu Yang,
  • Tao Zhang,
  • Chao Gao

Journal volume & issue
Vol. 16, no. 4
pp. 856 – 875

Abstract

Read online

Reinforced concrete (RC) columns are widely used as supporting structures for high-piled wharfs. The study of damage model of a RC column due to underwater explosion is a critical issue to assess the wharf’s antiknock security. In this study, the dynamic response and damage model of circular RC columns subjected to underwater explosions were investigated by means of scaled-down experiment models. Experiments were carried out in a 10.0 m diameter tank with the water depth of 2.25 m, under different explosive quantities (0.025 kg–1.6 kg), stand-off distances (0.0 m–7.0 m), and detonation depths (0.25 m–2.0 m). The shock wave load and dynamic response of experiment models were measured by configuring sensors of pressure, acceleration, strain, and displacement. Then, the load distribution characteristics, time history of test data, and damage models related to present conditions were obtained and discussed. Three damage models, including bending failure, bending-shear failure and punching failure, were identified. In addition, the experience model of shock wave loads on the surface of a RC column was proposed for engineering application.

Keywords