Química Nova (Dec 2006)

Determinação de contaminantes em óleos lubrificantes usados e em esgotos contaminados por esses lubrificantes

  • Eva Lúcia Cardoso Silveira,
  • Lília Basílio de Caland,
  • Carla Verônica Rodarte de Moura,
  • Edmilson Miranda Moura

DOI
https://doi.org/10.1590/S0100-40422006000600009
Journal volume & issue
Vol. 29, no. 6
pp. 1193 – 1197

Abstract

Read online

A simple and reliable ashing procedure is proposed for the preparation of used lubricating oil samples for the determination of Zn, Fe, Pb, Ni and Cu by the flame atomic absorption spectrometry technique. Sulphanilic acid was added to oil samples, the mixture coked and the coke ashed at 550 ºC. The solutions of the ash were analysed by flame AAS for these metals. The quantification limits were 38.250 µg g-1 for Zn, 4.550 µg g-1 for Fe, 1.562 µg g-1 for Pb, 1.450 µg g-1 for Ni, and 0.439 µg g-1 for Cu. The determinations, in lubricating oil, showed good precision and accuracy with recoveries between 90 and 110 %, indicating a negligible matrix effect in the experiments using addition of analyte, with relative standard deviation lower than 5%. The results for analysis of wastewater contamined by theses lubricants showed a very high relative standard deviation.

Keywords