IEEE Access (Jan 2018)

Permeance Analysis and Calculation of the Double-Radial Rare-Earth Permanent Magnet Voltage-Stabilizing Generation Device

  • Xueyi Zhang,
  • Qinjun Du,
  • Shilun Ma,
  • Huihui Geng,
  • Wenjing Hu,
  • Zhiwu Li,
  • Guoqiang Liu

DOI
https://doi.org/10.1109/ACCESS.2018.2792448
Journal volume & issue
Vol. 6
pp. 23939 – 23947

Abstract

Read online

The structure and magnetic circuit of the modern permanent magnet (PM) generator are often very complicated, which makes the traditional finite element analysis of magnetic field highly difficult. This paper establishes an equivalent magnetic circuit model of a new double-radial PM generator using the traditional equivalent circuit method and data analysis, introduces the calculation formulas of permeance and leakage permeance (LP) in magnetic circuits in detail, analyzes the influence factors of the LP, and provides the solutions. These studies will have a certain guiding significance for the design and optimization of generator circuits. To obtain the best matching parameters, the main parameters of the generator are tested and analyzed, such as the thickness of PM steel in the magnetization direction, length of PM steel, number of pole pairs, and the thickness of spacer bush. Finally, a prototype is tested, and the results show that the output characteristics of the designed double-radial PM voltage-stabilizing generation device are very good.

Keywords