Arquivos Brasileiros de Cardiologia (Aug 2006)
Versão em português, adaptação transcultural e validação de questionário para avaliação da qualidade de vida para pacientes portadores de marcapasso: AQUAREL The portuguese version, cross-cultural adaptation and validation of specific quality-of-life questionnaire - AQUAREL - for pacemaker patients
Abstract
RESUMO OBJETIVO: Traduzir, adaptar culturalmente e avaliar a reprodutibilidade e a validade da versão em português do questionário AQUAREL (Assessment of QUAlity of life and RELetad events), específico para avaliação da qualidade de vida em portadores de marcapasso cardíaco. MÉTODOS: Foram avaliados 202 pacientes portadores de marcapasso, sendo 63 na etapa de adaptação cultural e 139 pacientes na avaliação da reprodutibilidade e da validade. A tradução do questionário foi revista até que todas as questões alcançassem entendimento correto por > 85% dos pacientes. A reprodutibilidade da versão final foi testada pela aplicação do questionário em duas entrevistas em 69 pacientes, realizadas por um único entrevistador. A validade foi aferida pela correlação entre os escores obtidos nos domínios do AQUAREL e os domínios do questionário SF36, a classificação funcional e a distância caminhada no teste de seis minutos. RESULTADOS: A consistência interna do AQUAREL foi adequada, com índices Alfa de Cronbach variando de 0,59 a 0,85. A reprodutibilidade foi boa, com coeficientes de correlação elevados (0,68-0,89) e distribuição aleatória dos dados obtidos no gráfico de Bland and Altman, sem viés sistemático dos valores obtidos. Houve associação significativa (p OBJECTIVE: To translate, to make the cultural adaptation and to evaluate reproducibility and validity of the Portuguese version of the AQUAREL (Assessment of QUAlity of life and RELated events) questionnaire, which is a specific tool to assess quality of life in pacemaker patients. METHODS: We evaluated 202 pacemaker patients: 63 patients during the cross-cultural adaptation stage and 139 during the reproducibility and validity evaluation stages. The questionnaire translation was reviewed repeatedly until > 85% of patients correctly understood the questions. Reproducibility of the final version was tested in 69 patients in whom the interview was performed twice by the same researcher. Validity was checked by the correlation between scores obtained in AQUAREL domains and those obtained in SF36 domains, in the functional class and the distance walked in the six-minute test. RESULTS: The internal consistency of AQUAREL was adequate, with Cronbach’s alpha coefficient varying between 0.59 and 0.85. Reproducibility was good, with high correlation coefficients (0.68-0.89) and random distribution of data in Bland and Altman plots, without systematic bias. A significant association was observed among AQUAREL domains and those obtained in SF36 domains and the functional class (p<0.01), although significant correlations with the distance walked in the six-minute test were not found. CONCLUSION: The Portuguese version of the AQUAREL questionnaire is easy and rapid to apply, and could be used as a specific questionnaire to assess quality of life in pacemaker patients.
Keywords